AMERICAN INDUSTRIAL SUPPLY INC -- TEF-LUBE -- 6850-00N065416
=====================  Product Identification  =====================

Product ID:TEF-LUBE
MSDS Date:11/10/1988
FSC:6850
NIIN:00N065416
=== Responsible Party ===
Company Name:AMERICAN INDUSTRIAL SUPPLY INC
Box:10996
City:BURBANK
State:CA
ZIP:91510-0996
Country:US
Info Phone Num:818-841-7788
Emergency Phone Num:818-841-7788
Preparer's Name:A.F. ARMER
CAGE:0WE73
=== Contractor Identification ===
Company Name:AMERICAN INDUSTRIAL SUPPLY INC
Address:4514 VANOWEN ST.
Box:10996
City:BURBANK
State:CA
ZIP:91506-0996
Country:US
Phone:800-366-0961/818-841-7788
CAGE:0WE73

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA
    313) (CERCLA)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 52%
OSHA PEL:350 PPM
ACGIH TLV:350 PPM;450 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;
    (TETRAFLUOROETHYLENE MIXTURE) (FREON 113) (SARA 313)
CAS:76-13-1
RTECS #:KJ4000000
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM;1250 STEL
Ozone Depleting Chemical:1

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

Ingred Name:BUTANE (MFR'S INVALID CAS NO:106-9)
CAS:106-97-8
RTECS #:EJ4200000
OSHA PEL:800 PPM
ACGIH TLV:800 PPM

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:EXCESSIVE INHAL CAN CAUSE
    RESP IRRIT, DIZZ, NAUS, HDCHS & UNCON. CHRONIC OVEREXP MAY CAUSE
    LIVER, KIDNEY/LUNG DISEASE, ANEMIA, CORONARY DISEASE/RHYTHM
    DISORDERS OF HEART. SKIN:PRLNG/RPTD C ONT CAN CAUSE MOD IRRIT,
    DEFAT & DERM. INGEST:SINGLE DOSE TOX IS LOW TO MOD. IF VOMIT
    OCCURS, ASPIR OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MATL INTO LUNGS CAN CAUSE CHEM PNEUM &
    SYSTEMIC EFTS. EYE CONT:CAN CAUSE SEV IRRIT, REDNESS, TEARING &
    BLURRED VISION. CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM
    TO EPINEPHRINE IN LAB  ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS.
    ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRATINDICATED EXCEPT
    (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER &
    LOWER LIDS. GET MEDICAL ATTENTION. SKIN:WASH EXPOSED AREAS W/SOAP &
    WATER. INHAL:REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT,
    ADMINISTER	OXYGEN. IF BREATHING STOPS GIVE ARTIFICIAL RESPIRATION.
    GET MEDICAL ATTENTION. INGEST:DO NOT INDUCE VOMITING. GET MEDICAL
    ATTENTION. ASPIRATION OF MATL INTO LUNGS DUE TO VOMIT CAN CAUSE
    CHEM PNEUM.

=====================  Fire Fighting Measures  =====================

Flash Point Method:OC
Flash Point:150F,66C
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
    PROT EQUIP . KEEP CNTNRS COOL. USE EQUIP/SHIELDING REQD TO PROT
    PERS AGAINST BURSTING, RUPTURING/ (SUPDAT)
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
    INCLUDE HCL & PHOSGENE . AT ELEVATED TEMPERATURES (>120F)
    CONTAINERS MAY VENT, RUPTURE OR BURST.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CLEAN UP AREA BY MOPPING OR W/ABSORBENT
    MATERIALS & PLACE IN CLOSED CONTAINERS FOR DISPOSAL. CONTACT
    FEDERAL, STATE OR LOCAL AUTHORITIES FOR APPROVED DISPOSAL
    PROCEDURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE
    120F. DO NOT EAT, DRINK OR SMOKE IN WORK AREA.
Other Precautions:PLEASE READ & FOLLOW DIRECTIONS ON PROD LBL; THEY ARE
    YOUR BEST GUIDE TO USING THIS PROD IN MOST EFTIVE WAY & THEY ALSO
    GIVE NEC SFTY PRECS TO PROT YOUR HLTH. NO SMOKING IN AREA OF USE.
    DO NOT USE IN  GEN VICIN OF ARC WELDING, OPEN (SUPDAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC TYPE RESPIRATOR
    ACCEPTABLE IF CONCENTRATION IS 350-1000 PPM.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) &/OR LOCAL EXHAUST
    VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:NEOPRENE, NITRILE RUBBER OR (SUPP DATA)
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS BEFORE EATING.
Supplemental Safety and Health
FIRE FIGHT PROC:VENTING CNTNRS. EFTS OF OVEREXP:FOR LIFE-SUSTAINING
    USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS . OTHER
    PREC:FLAMES/HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE FORM OF  HCL
    &/OR PHOSGENE . PROT GLOVES:POLYVINYL CHLORIDE GLOVES.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:142F,61C
Vapor Pres:46
Spec Gravity:1.335 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:MILKY WHITE LIQUID; MILD SWEETISH ODOR.
Percent Volatiles by Volume:98

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS, ALUMINUM & OTHER REACTIVE METALS.
Stability Condition to Avoid:DO NOT EXPOSE TO TEMPERATURES ABOVE 120F.
Hazardous Decomposition Products:AT ABNORMALLY HIGH TEMPERATURES,
    POSSIBLE TRACE AMOUNTS OF PHOSGENE OR HYDROGEN CHLORIDE.
Conditions to Avoid Polymerization:CONTACT W/HIGHLY ALKALINE MATERIAL
    SUCH AS SODIUM HYDROXIDE & POTASSIUM HYDROXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WHEN USED PROPERLY, AEROSOL PRODS DO NOT
    GENERATE HAZ WASTE. EMPTY DE-PRESSURIZED CNTNRS CAN NOT BE REUSED &
    SHOULD BE WRAPPED & PUT IN PERMITTED WASTE MANAGEMENT FACILITY.
    CONSULT FED, STATE & LOC DI SP AUTHS FOR APPROVED PROCEDURES.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.