PPG INDUSTRIES INC COATINGS & RESINS GROUP -- DP60LF EPOXY PRIMER -- 8010-00F050509
=====================  Product Identification  =====================

Product ID:DP60LF EPOXY PRIMER
MSDS Date:05/12/1994
FSC:8010
NIIN:00F050509
=== Responsible Party ===
Company Name:PPG INDUSTRIES INC COATINGS & RESINS GROUP
Address:4325 ROSANNA DR
Box:9
City:ALLISON PARK
State:PA
ZIP:15101-5000
Country:US
Info Phone Num:412-492-5555
Emergency Phone Num:304-843-1300
CAGE:DO542
=== Contractor Identification ===
Company Name:PPG INDUSTRIES INC. COATINGS & RESINS GP
Address:4325 ROSEANNA DR PO BOX 9
Box:9
City:ALLISON PARK
State:PA
ZIP:15101
Phone:412-492-5555
CAGE:DO542

=============  Composition/Information on Ingredients  =============

Ingred Name:COMPLEX INORGANIC BLUE PIGMENT, FERRIC FERROCYANIDE PIGMENT
    *96-2*
CAS:14038-43-8
RTECS #:LJ8200000
Fraction by Wt: 1-2%
OSHA PEL:15 MG/CUM
ACGIH TLV:10 MG/CUM

Ingred Name:CARBONIC ACID, CALCIUM SALT (1:1), CALCIUM CARBONATE,
    DURAMITE
CAS:471-34-1
RTECS #:FF9335000
Fraction by Wt: 10-15%
Other REC Limits:10 MG/CUM (DUST)

Ingred Name:BARIUM SULFATE, BARYTES   *96-2*
CAS:7727-43-7
RTECS #:CR0600000
Fraction by Wt: 10-15%
OSHA PEL:10 MG/CUM
ACGIH TLV:10 MG/CUM

Ingred Name:ZINC PHOSPHATE, ZINC ORTHOPHOSPHATE
CAS:7779-90-0
RTECS #:TD0590000
Fraction by Wt: 5-10%
Other REC Limits:10 MG/CUM
OSHA PEL:15 MG/CUM
ACGIH TLV:10 MG/CUM

Ingred Name:TITANIUM DIOXIDE, TITANIUM OXIDE  (SUSPECTED ANIMAL
    CARCINOGEN, IARC GROUP 3)	*96-2*
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 5-10%
OSHA PEL:15 MG/CUM
ACGIH TLV:10 MG/CUM (DUST)

Ingred Name:XYLENE, DIMETHYLBENZENE, XYLOL     (IARC - GROUP 3)  *96-2*
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 2-5%
Other REC Limits:100 PPM
OSHA PEL:100 PPM
ACGIH TLV:100 PPM, SKIN
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SOLVENT NAPHTHA, PETROLEUM, LIGHT AROMATIC, HIGH FLASH
    AROMATIC NAPHTHA, C8&10 AROMATIC HYDROCARBON	    *96-2*
CAS:64742-95-6
RTECS #:WF3400000
Fraction by Wt: 5-10%

Ingred Name:2-HEPTANONE, METHYL N-AMYL KETONE
CAS:110-43-0
RTECS #:MJ5075000
Fraction by Wt: 10-15%
Other REC Limits:50 PPM
OSHA PEL:465 MG/CUM
ACGIH TLV:233 MG/CUM

Ingred Name:HEXONE, METHYL ISOBUTYL KETONE (MIBK), 4-METHYL-2-PENTANONE
CAS:108-10-1
RTECS #:SA9275000
Fraction by Wt: 5-10%
Other REC Limits:50 PPM
OSHA PEL:410 MG/CUM
ACGIH TLV:205 MG/CUM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:TOLUENE (IARC CARC- GROUP 3)     *96-2*
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 2-5%
Other REC Limits:375 MG/CUM
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:2-BUTOXYETHANOL (ETHYLENE GLYCOL MONOBUTYL ETHER), BUTYL
    CELLOSOLVE, BUTYL GLYCOL, GLYCOL ETHER EB  * 96-2 *
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 2-5%
Other REC Limits:25 PPM (SKIN)
OSHA PEL:50 PPM (SKIN)
ACGIH TLV:25 PPM (SKIN)

Ingred Name:FILM FORMERS, RESINS, AND ADDITIVES
Fraction by Wt: 2-5%

Ingred Name:CRYSTALLINE-QUARTZ SILICA, SILICA DUST    (SUSPECTED HUMAN
    CARCINOGEN BY IARC-GROUP 2A; SUSPECTED CARCINOGEN NTP) *96-2*
CAS:14808-60-7
RTECS #:VV7330000
Fraction by Wt: <1%
Other REC Limits:0.05 MG/CUM (NIOSH)
OSHA PEL:10 MG/CUM %RESP SIO2
ACGIH TLV:0.1 MG/CUM RESP DUST

Ingred Name:BARIUM COMPOUNDS
Fraction by Wt: 10-15%

Ingred Name:GLYCOL ETHERS
Fraction by Wt: 2-5%

Ingred Name:BISPHENOL A DIGLYCIDYL ETHER RESIN, EPOXY RESIN, EPON 820, 
    ARALDITE 6004, AMINE ADDUCT, ARALDITE GY250    *96-2*
CAS:25068-38-6
RTECS #:KD4380000
Fraction by Wt: 10-15%

Ingred Name:SILICA, AMORPHOUS, PRECIPITATED AND GEL, SYNTHETIC
    CRYSTALLINE-FREE SILICA GEL *96-2*
CAS:112926-00-8
RTECS #:VV7315000
Fraction by Wt: 1-2%
ACGIH TLV:10 MG/CUM

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:HARMFUL IF SWALLOWED, ABSORBED THROUGH
    THE SKIN & INHALED. EYES: IRRITATION. SKIN: IRRITATION, ALLERGIC
    REACTIONS. INHALATION: IRRITATION TO EYES, NOSE & THROAT. REPEATED
    EXPOSURE TO HIGH VAPOR CONCEN TRATIONS MAY CAUSE IRRITATION OF THE
    RESPIRATORY SYSTEM & PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. (SEE
    SUPP)
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION, EYE WATERING, HEADACHES, NAUSEA,
    DIZZINESS, LOSS OF COORDINATION, REDNESS, ITCHING, BURNING, VISUAL
    DISTURBANCES, DRYNESS, CRACKING, SWELLING.

=======================  First Aid Measures  =======================

First Aid:INGESTION: DON'T INDUCE VOMITING. EYES: FLUSH IMMEDIATELY
    W/PLENTY OF WATER FOR 15 MINS. SKIN: FLUSH W/WATER, FOLLOWED BY
    WATERLESS CLEANER & SOAP. INHALATION: REMOVE TO FRESH AIR. GIVE CPR
    IF NEEDED.	INGESTION: CONTACT A POISON CONTROL CENTER & HAVE
    MATERIAL SAFETY DATA SHEET INFORMATION AVAILABLE. OBTAIN MEDICAL
    ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:80F
Lower Limits:1.2
Extinguishing Media:CO2, DRY CHEMICAL/UNIVERSAL AQUEOUS FILM FORMING
    FOAM.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. WATER SPRAY
    MAY BE USED TO COOL CLOSED CONTAINERS. IF WATER IS USED, FOG
    NOZZLES ARE PREFERABLE. WEAR SCBA.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
    FROM HEAT, ELECTRICAL EQUIPMENT & OTHER IGNITION SOURCES. DON'T
    APPLY TO HOT SURFACES. (SEE SUPP)

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE MAXIMUM VENTILATION. ONLY PERSONNEL
    EQUIPPED W/PROPER RESPIRATORY & SKIN/EYE PROTECTION, PERMITTED.
    REMOVE IGNITION SOURCES. TAKE UP W/SAWDUST, VERMICULITE/OTHER
    ABSORBENT MATERIAL & PLACE INTO CO NTAINERS FOR DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:GROUND CONTAINER WHEN POURING. AVOID
    FREE FALL OF LIQUIDS IN EXCESS OF A FEW INCHES. DON'T STORE >120F.
Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING &
    INHALING THE CONTENTS CAN BE HARMFUL/FATAL.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED AIR PURIFYING/AIR
    SUPPLIED RESPIRATORS.
Ventilation:GENERAL DILUTION/LOCAL EXHAUST VENTILATION.
Protective Gloves:NITRILE/NEOPRENE RUBBER
Eye Protection:CHEMICAL SPLASH GOGGLES/FULL FACE SHIELD
Other Protective Equipment:IMPERMEABLE APRON.
Supplemental Safety and Health
UNUSUAL FIRE CONT'D: TOXIC GASES MAY FORM WHEN PRODUCT IS CONTACTED BY
    FLAME/HOT SURFACES. HEALTH HAZARDS CONT'D: CRYSTALLINE
    SILICA/QUARTZ MAY LEAD TO SILICOSIS. CLOSED CONTAINERS MAY EXPLODE
    WHEN EX POSED TO EXTREME HEAT.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:230-381.2F
Vapor Pres:7.5
Vapor Density:>1
Spec Gravity:1.36
Evaporation Rate & Reference:(BU OAC =100): 79
Solubility in Water:4.7
Appearance and Odor:VISCOUS LIQUID W/CHARACTERISTIC ODOR OF THE
    SOLVENTS LISTED.
Percent Volatiles by Volume:61.19

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG MINERAL ACIDS/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES, ELECTRICAL
    EQUIPMENT & OTHER IGNITION SOURCES. TEMP >120F.
Hazardous Decomposition Products:HEATED, WELDING, BRAZING/FLAME
    CUTTING: CO, HYDROGEN CHLORIDE, CHLORINE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
    REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED/DISPOSED OF
    THROUGH AN APPROVED WASTE MANAGEMENT FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.