AIR PRODUCTS & CHEMICALS INC -- NITROGEN DIOXIDE -- 6830-00N079890
===================== Product Identification =====================
Product ID:NITROGEN DIOXIDE
MSDS Date:08/01/1991
FSC:6830
NIIN:00N079890
=== Responsible Party ===
Company Name:AIR PRODUCTS & CHEMICALS INC
Address:7201 HAMILTON BLVD
City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Info Phone Num:215-481-8257
Emergency Phone Num:800-523-9374
CAGE:00742
=== Contractor Identification ===
Company Name:AIR PRODUCTS AND CHEMICALS INC
Address:7201 HAMILTON BLVD
Box:City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Phone:800-345-3148/ 800-752-1597
CAGE:00742
============= Composition/Information on Ingredients =============
Ingred Name:NITROGEN DIOXIDE (SARA 302)
CAS:10102-44-0
RTECS #:QW9800000
OSHA PEL:C 5 PPM
ACGIH TLV:3 PPM/5 STEL
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Ingred Name:NITROGEN TETROXIDE
CAS:10544-72-6
RTECS #:QX1575000
OSHA PEL:N/K
ACGIH TLV:N/K
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Ingred Name:SUP DAT: DIRECT CONTACT WITH LIQUID CAN HAVE A CORROSIVE
EFFECT ON SKIN OR EYES.
RTECS #:9999999ZZ
Ingred Name:FIRST AID PROC: PASSED (AT LEAST 72 HRS). ANY PHYSICAL
EXERTION DURING THIS PERIOD SHOULD BE DISCOURAGED AS IT (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: MAY INCR SEV OF PULM EDEMA/CHEM PNEUMIT. BED REST IS
INDICATED. UNCON PERS SHOULD BE MOVED TO UNCONTAM (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5: AREA. GIVEN MOUTH-TO-MOUTH RESUSCITATION & SUPP
OXYGEN. ONCE RESP HAS BEEN RESTORED, THEY SHOULD BE (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6: TREATED AS ABOVE. EYES: PERS W/POTENTIAL EXPOS TO
NITROGEN DIOXIDE SHOULD NOT WEAR CONT LENSES. FLUSH (ING 8)
RTECS #:9999999ZZ
Ingred Name:ING 7: CONTAM EYES W/LGE QTYS OF WATER. HOLD EYELIDS OPEN
W/FINGERS TO ASSURE COMPLETE FLUSHING. CONTINUE FOR (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8: MININUM OF 15 MIN. SKIN: FLUSH W/LARGE QUANTITIES OF
WATER. REMOVE CONTAM CLOTHING & WASH BEFORE REUSE. (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9: INGESTION: CALL MD IMMEDIATELY .
RTECS #:9999999ZZ
Ingred Name:WASTE DISP METH: VALVE PROTECTION CAP IN PLACE. FOR
EMERGENCY DISPOSAL ASSIST, CALL "800" EMER PHONE NUMBER HEREIN.
RTECS #:9999999ZZ
Ingred Name:OTHER PREC: FLOW INTO CYL. FOR ADDNL HNDLG RECS CONSULT AIR
PRODS SPECIALTY GAS CATALOG SFTY & TECHNICAL INFO (ING 13)
RTECS #:9999999ZZ
Ingred Name:ING 12: SECTION/COMPRESSED GAS ASSOCIATION PAMPHLET P-1.
PROTECT CYLS FROM PHYSICAL DMG. STORE IN COOL, DRY, (ING 14)
RTECS #:9999999ZZ
Ingred Name:ING 13: WELL-VENTD AREA AWAY FROM HEAVILY TRAVELED AREAS &
EMER EXITS. DO NOT ALLOW TEMP WHERE CYLS ARE STORED (ING 15)
RTECS #:9999999ZZ
Ingred Name:ING 14: TO EXCEED 125F (51C). CYLS SHOULD BE STORED UPRIGHT
& FIRMLY SECURED TO PVNT FALLING/BEING KNOCKED OVER.(ING 16)
RTECS #:9999999ZZ
Ingred Name:ING 15: FULL & EMPTY CYLS SHOULD BE SEGREGATED. USE "FIRST
IN-FIRST OUT" INVENTORY SYS TO PVNT FULL CYLS BEING (ING 17)
RTECS #:9999999ZZ
Ingred Name:ING 16: STORED FOR EXCESS PERIODS OF TIME. FOR ADDNL STOR
RECS CONSULT AIR PRODS SPECIALTY GAS CATALOG SFTY & (ING 18)
RTECS #:9999999ZZ
Ingred Name:ING 17: TECHNICAL INFO SECTION/COMPRESSED GAS ASSOCIATION
PAMPHLET P-1. ANHYDROUS NITROGEN DIOXIDE IS NON-CORR (ING 19)
RTECS #:9999999ZZ
Ingred Name:ING 18: TO MOST METALS AT NORM TEMPS. IT DOES CORRODE
COPPER & ITS ALLOYS. TEFLON IS THE PREF GASKET MATL. (ING 20)
RTECS #:9999999ZZ
Ingred Name:ING 19: KEEP EQUIP SCRUPULOUSLY DRY. COMPRESSED GAS CYLS
SHOULD NOT BE REFILLED EXCEPT BY QUALIFIED PRODUCERS (ING 21)
RTECS #:9999999ZZ
Ingred Name:ING 20: OF COMPRESSED GASES. SHIPMENT OF COMPRESSED GAS CYL
WHICH HAS NOT BEEN FILLED BY THE OWNER/WITH HIS (ING 22)
RTECS #:9999999ZZ
Ingred Name:ING 21: (WRITTEN) CONSENT IS A VIOLATION OF FEDERAL LAW
(49CFR).
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAPS ARE A STRONG IRRIT TO PULM
TRACT. CONT W/LIQ CAUSES SEV CORR ACTION ON SKIN/EYES. INITIAL
SYMPS OF INHAL MAY BE MOD & INCL IRRIT OF EYES & THROAT, TIGHTNESS
OF CHEST, HDCH, NAUS & GRADUAL LOSS OF STRENGTH. SEV SYMPS MAY BE
DELAYED (POSS FOR 5-7 HRS) & INCL CYANOSIS (BLUE/PURPLE SKIN
COLOR),(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: INCRD DFCLTY IN BRTHG, IRREG RESP,
LISTLESSNESS & POSS DEATH DUE TO PULM EDEMA (ABNORMAL FLUIDS
BUILD-UP IN LUNGS) IN UNTREATED CASES. TOX PROPERTIES: VAP IS
HIGHLY TOX & HAZ BECAUSE OF ITS ABILITY TO CAUSE DELAYED CHEM
PNEUMIT (INFLAMM OF LUNGS) & PULM EDEMA. CHRONIC/RPTD EXPOS MAY
CAUSE PERM (SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:PROMPT MED ATTN IS REQUIRED IN ALL CASES OF OVEREXP TO
NITROGEN DIOXIDE & ITS BY-PRODS. RESCUE PERS SHOULD BE EQUIPPED
W/APPROP PROT EQUIP (NIOSH APPRVD SCBA, ETC) TO PVNT UNNEC EXPOS.
INHAL: CONSCIOU S PERS SHOULD BE CARRIED (NOT ASSISTED)TO UNCONTAM
AREA & BREATHE FRESH AIR SUPPLEMENTED W/OXYGEN. KEEP WARM, QUIET &
UNDER COMPETENT MED OBSERVATION UNTIL DANGER OF DELAYED PULM EDEMA
HAS (ING 4)
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER SPRAY OR FOG. DO NOT USE HALOGENATED
MATERIALS.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP . IF
W/OUT RISK, STOP FLOW OF GAS TO FIRE. FROM SAFE DIST, COOL CYLS
W/WATER SPRAY UNTIL WELL AFTER FIRE IS OUT.
Unusual Fire/Explosion Hazard:STRONG OXIDIZING AGENT; WILL SUPPORT
COMBUSTION. CYLINDERS EXPOSED TO FIRE/INTENSE HEAT MAY VENT
RAPIDLY/EXPLODE. RUNOFF FROM FIRE CONTROL MAY CAUSE POLLUTION.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN TO
PURGE PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CYLINDER/CYLINDER VALVE, CALL "800" EMER PHONE NUMBER LISTED
HEREIN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:VALVE PROT CAPS & VALVE OUTLET
THREADED PLUGS MUST REMAIN IN PLACE UNLESS CYL IS SECURED W/VALVE
OUTLET PIPED TO USE POINT.
Other Precautions:USE ONLY IN WELL-VENTD AREAS. DO NOT DRAG, SLIDE/ROLL
CYLS. USE SUITABLE HAND TRUCK FOR CYL MOVEMENT. DO NOT HEAT CYL BY
ANY MEANS TO INCR DISCHARGE RATE OF PROD FROM CYL. USE CHECK
VALVE/TRAP IN DISC HARGE LINE TO PVNT HAZ BACK (ING 12)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPROVED POSITIVE AIR LINE WITH MASK OR
SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:USE HOOD W/FORCED VENT &/LOC EXHST TO PREVENT ACCUM ABOVE
TWA. LOC REGS MAY REQUIRE SPECIFIC EQUIP FOR STORAGE & USE.
Protective Gloves:RUBBER OR TEFLON.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG (SUP DAT)
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . CHEMICAL RESISTANT OVERGARMENTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O: DECOMPOSES TO NITRIC ACID & NITROUS ACIDS. EYE PROT: &
FULL LENGTH FSHLD . EFTS OF OVEREXP: DECR IN PULM FUNC (SILO
FILLER'S DISEASE). WARNING PROPERTIES OF NITROGEN DIOXIDE ARE SEV
LIMITED IN THAT DANGEROUS LEVELS MAY BE INHALED BEFORE SIGNIFICANT
DISCOMFORT/IRRIT IS FELT. (ING 3)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:70.0F,21.1C
Vapor Pres:14.8 PSIA
Spec Gravity:2.62 (AIR=1)
Solubility in Water:SUP DAT
Appearance and Odor:YELLOW-BROWN LIQUID TO REDDISH-BROWN GAS WITH ACID
SUFFOCATING ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
HYDROCARBONS, FUELS, ALCOHOLS, ORGANIC MATERIALS.
Stability Condition to Avoid:TEMPERATURES ABOVE 320F (160C).
Hazardous Decomposition Products:DECOMPOSES ON CONT W/WATER TO PRDCE
NITRIC & NITROUS ACIDS. IT ACTS AS CATALYST FOR EXPLO RXN OF OXYGEN
& HYDROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:ALL FED, STATE & LOC REGS REGARDING HLTH &
POLLUTION SHOULD BE FOLLOWED IN WASTE DISP. CONT MFR FOR SPECIFIC
RECS. DO NOT DISP OF UNUSED QTYS. RETURN PROPERLY LABELED SHIPPING
CONTR TO MFR W/VALVE(S) TIGHTLY CLSD, OUTLET SEALS SECURED & (ING
11)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.